  • What is the purpose of a pressure relief valve in the fire pump discharge system, and how should it be tested during a run test?
  • How does a fire pump run test verify ability to sustain rated discharge pressure under fluctuating demands?
  • Backflow prevention devices are designed to prevent backflow into which source?
  • Which statement about the Authority Having Jurisdiction (AHJ) is correct?
  • Which condition is identified as the most common cause of horizontal pump failure?
  • What should be documented to validate the start/stop sequence during a run test for compliance and traceability?
  • The state agency responsible for adopting a schedule of fees paid by licensees to cover administrative costs is which entity?
  • Which entities should be notified for a significant abnormality observed during testing?
  • What happens when the transfer switch operates?
  • In a suction lift scenario, which pump type is appropriate?
  • During a pump run test, how does ambient temperature affect results and what precaution should you take?
  • When should notification to the alarm facility be performed?
  • Fuel tank level should be maintained at what level?
  • What is the minimum observed fuel tank level specified?
  • A license may be revoked or denied for which of the following reasons?
  • Which measurement is not typically recorded during a full-flow test on a fire pump?
  • Suction bypass valves should be set to what position during normal operation?
  • During routine checks, what action sequence is recommended for flexible hoses and connections?
  • Read which flow condition as follows?
  • Which issue is a common cause of reduced suction or discharge pressure in a pump?
  • For the battery charger and charge rate, what routine is required?
  • General electrical system inspection cadence: Which action sequence is recommended?
  • The annual renewal period shall begin on December 31 and end on January 1 preceding the license year. Which dates define this period?
  • Which of the following safety steps should be observed when performing a run test under real-fire conditions or with variable water supply?
  • Tank Level: Which maintenance action sequence is recommended?
  • Explain the role of the transfer switch in a fire pump system run test and how it is tested.
  • Abnormalities observed should be reported to whom?
  • If cranking voltage on a 24 V system exceeds 18 V, what action and cadence should be followed?
  • How would you differentiate between cavitation and bearing noise during a run test?
  • Who will assign an impairment coordinator to comply with Chapter 15 requirements?
  • What is the primary purpose of a running test on a fire pump?
  • Which instrument indicates the oil level in the motor?
  • Pump packing glands should have?
  • The offense of intentionally constructing or maintaining a system that results in great bodily injury or death is what?
  • If a run test reveals excessive engine exhaust emissions, what steps should be taken?
  • When measuring motor voltage, what tolerance is acceptable relative to the rated nameplate value?
  • Any person who violates any provision of this chapter or any regulation or building standard adopted by the State Fire Marshal pursuant to Section 13195 is guilty of?
  • The controller selector switch should be in which position for automatic control?
  • Which weekly maintenance action is recommended for the exhaust system to prevent leaks?
  • If the license fee is not paid on or before which date preceding the license year, a 50 percent penalty applies?
  • What is the purpose of logging data during a run test?
  • Oil Level: Which maintenance action sequence is recommended?
  • What is the difference between auto-start and manual start mode for a fire pump, and when should each be used during a run test?
  • Which statement best describes priming differences between end-suction and vertical turbine pumps during testing?
  • The peak flow rate of a fire pump is 150% of its rated flow. Which statement is true?
  • What is the purpose of a remote annunciator panel, and what information should be displayed during a run test?
  • For the jacket water heater, what is the required inspection frequency?
  • How do you identify and correct an air-bound priming system during a run test?
  • Which statement best describes the AHJ roles?
  • Which factors determine the need to implement a standby power source for a run test?
  • What would be the peak flow rate of a fire pump?
  • Suction bypass valves should be set to what position?
  • The annual license validity period runs from January 1 to December 31. Which statement best reflects this period?
  • In a fire pump system, why is a relief valve used and how should it be tested for proper operation?
  • Diesel engine run time during the run test?
  • When testing a fire pump with a vertical turbine versus an end-suction pump, which considerations must be made?
  • Which facility should be notified when the alarm triggers?
  • What is the purpose of annunciator and alarm testing during run tests?
  • What indicates that engine oil or coolant readings are abnormal and require remediation before proceeding?
  • Which statement describes the normal phase rotation indicator when rotation is correct?
  • During normal operation, which statement describes the suction bypass valve position?
  • What action should be taken if a gauge is not accurate?
  • Why is calibration of pressure gauges essential before a run test?
  • Explain the procedure for re-priming after a loss of prime during a run test.
  • The installed safety relief valve shall be allowed to discharge under which condition?
  • Notification to alarm facility should be sent to which entities?
  • The annual license shall be valid for which period?
  • What weekly action should be taken to ensure adequate cooling water to the heat exchanger?
  • Which items should be captured in the run test record after testing?
  • Which devices should be tested together as part of the emergency power testing program?
  • Why is it essential to keep the test area clear of civilians and vehicles during a run test?
  • Cooling system Level: Which action sequence is recommended?
  • Increasing engine speed beyond the pump rated speed is acceptable?
  • For weekly checks of the general electrical system, which maintenance sequence is recommended?
  • If discharge valves are seized and cannot be opened during a run test, what is the proper course of action?
  • What is the role of standby personnel during a run test?
  • What is the first indication of a pump operating without water in its casing?
  • Battery case exterior clean & dry: Which action sequence is recommended?
  • Wet pit suction screens should be checked and cleaned when?
  • Any person who maliciously constructs or maintains a system which is known to be inoperable or impairs the operation shall be subject to?
  • What should you do if a gauge indicates an abnormal discharge pressure reading during the run test?
  • Which tests shall be performed?
  • Why is it important to test the jockey pump function separately from the main pump during run testing?
  • What position should the suction bypass valve be in?
  • A license may be revoked or denied for which of the following reasons?
  • In NFPA 20, what are the primary tests included in an annual run test?
  • Valves and fire department connections shall be?
  • Suction reservoir level should be kept at what level?
  • What is the role of a check valve in the suction line, and how would you verify it is functioning during a run test?
  • Tank float switch: Which action sequence is recommended?
  • If cranking voltage exceeds 9 V on a 12 V system, what action and cadence are specified?
  • What are the common indicators of an air leak in the suction line during a run test?
  • Backflow prevention is used to keep water from entering which system?
  • How can you verify the pump is delivering the correct flow at the correct head when test flow is not easily measured?
  • What is the function of the governor during a diesel fire pump run test?
  • After starting the engine and allowing the diesel fire pump to reach operating RPM, what must be verified before placing the pump in service?
  • For installations with an automatic transfer switch, which tests should be performed?
  • What is the weekly maintenance for the condition of flexible hoses and connections?
  • Suction reservoir level should be kept at what level?
  • What is the effect of ballast tanks on transient readings during rapid load changes or pump trips?
  • In the absence of a specified designee, who shall be considered the impairment coordinator?
  • What is the most common cause of horizontal pump failure?
  • Any person who maliciously constructs or maintains a system which proximately results in great bodily injury or death is a felony punishable by?
  • What is the primary purpose of a jockey pump in a fire pump system and how is it activated?
  • What is the required run time for the diesel engine during the weekly run test?
  • Which measurements are typically monitored to assess pump performance during a run test?
  • What is the consequence of insufficient net positive suction head (NPSH) on pump operation?
  • Circuit protection devices inspection: Which action sequence is recommended?
  • Equalize charge (battery) maintenance requires which weekly action?
  • Which of the following describes the steps to perform a post-test inspection after a run test?
  • For causing great bodily injury or death by maliciously constructing a system, what is the offense classification?
  • What maintenance instruction applies to exhaust system leakage during the run test?
  • General Inspection Electrical system: Which action sequence and cadence is recommended?
  • What is the purpose of conducting a full-flow test on a fire pump and what measurements are typically recorded?
  • Which of the following is the penalty for violating this chapter's provisions or regulations adopted by the State Fire Marshal?
  • How does a static test differ from a running test for fire pumps?
  • What weekly maintenance should be performed on drain exhaust condensate traps?
  • Abnormalities observed should be reported to which party?
  • The motor should accelerate to which speed during testing?
  • Which instrument is commonly used to locate hidden leaks during a pressure test?
  • How would you calculate the minimum acceptable discharge pressure during a test for a given system head, and what fluid properties matter?
  • What is the role of the suction gauge in a run test, and what readings indicate normal operation?
  • In a fire pump run test, ballast or surge tanks dampen pressure fluctuations and water hammer; when would they affect test results?
  • What is the purpose of a check valve in the discharge piping during a run test?
  • Water in system: Which maintenance action sequence is recommended?
  • What steps would you take if during a test, the discharge pressure falls below the required level while the engine speed remains at rated?
  • Which party designates an impairment coordinator if no designee is specified?
  • The reverse phase alarm pilot light should be in which state under normal conditions?
  • What should be done to ensure safe water supply during a run test?
  • During a run test, rising temperature in the pump bearing housing is observed. What are the possible causes and the recommended remedy?
  • The oil level in the motor sight glass should be within which range?
  • Define cavitation in a fire pump impeller and identify typical indicators observed during a run test.
  • Battery electrolyte level should be checked how often?
  • Penalty for malicious inoperable system causing great bodily injury or death?
  • Lube oil heater maintenance frequency?
  • For a 24-volt system, cranking voltage over 18 volts requires what action and cadence?
  • The installed safety relief valve shall be?
  • If a high vibration reading exceeds acceptable limits during a run test, what is the first step?
  • Which records shall be maintained by the property owner for the life of the system?
  • During inspection, the pump assembly should appear to be in which condition?
  • The purpose of the inspection shall be to verify that the pump assembly appears to be?
  • Define net positive suction head in the context of fire pump operation and why it's important.
  • Gauges shall be replaced every ___ years or tested every ___ years using a calibrated gauge?
  • During a run test, abnormal vibration may be caused by which of the following, and how should it be diagnosed?
  • Lockout/tagout procedures during a run test are used to prevent what risk?
  • Why is it important to verify the engine governor/engine speed during run test, and what is a typical target RPM range for a diesel fire pump?
  • Why should the shutdown be documented in the test record?
  • What post-test activity ensures the performance data is captured for review?
  • What is the proper sequence for safely shutting down a fire pump after a run test?
  • For how long should the property owner retain testing and maintenance records?
  • During testing, the flow readout includes which measurements?
  • Exercise isolation switch & CB: Which action and cadence is recommended?
  • How is a jockey pump typically activated in a fire pump system?
  • If the cranking voltage on a 12-volt system exceeds 9 volts, which action is specified and how often?
  • Specific gravity or state of charge of the battery should be checked at what interval?
  • What is the purpose of placing barriers around the test area during a run test?
  • During ATS testing, what is the purpose of simulating a power failure while the pump is at peak load?
  • Electric fire pump run time during the test?
  • Which statement about AHJ membership is true?
  • How do you verify proper priming of a positive displacement fire pump, and what are signs of improper priming?
  • What is the first critical step in the re-priming process?
  • Which of the following is NOT listed as a common cause for a pump not achieving starting at the scheduled time in auto mode during a run test?
  • Which audible cue indicates a pump may be running dry?
  • Which maintenance steps are specified for solenoid valve operation in the run test procedure?
  • The controller pilot light should be what during normal operation?
  • Which symptom most clearly indicates cavitation during a run test?
  • Gauges shall be inspected to verify they are in good condition and that normal pressure is being maintained?
  • What is a common cause of pump suction loss or discharge pressure failure?
  • What weekly action is specified for water pump(s)?
  • Which maintenance sequence is required for valves and fire department connections?
  • The normal phase rotation pilot light should be in which state?
  • During a run test, which sequence correctly describes starting a diesel fire pump and preparing it for service?
  • Before operating a horizontal pump, what is the acceptable drop per second in the packing?
  • What action should you take if the suction gauge indicates abnormally low suction pressure during a run test?
  • Who has the right to establish a secondary schedule of fees?
  • During a zero-flow test, what actions are performed and what is its primary purpose?
  • What weekly action should be taken regarding the condition of flexible hoses and connections?
  • The transfer switch normal pilot light should be what during normal operation?
  • Circuit breakers or fuses: Which action sequence is recommended?
  • During a run test, what observation indicates that the engine cooling system is functioning properly?
  • How would you identify a leak in the discharge piping under test, and what steps would you take to locate and repair it?
  • Which state should the observed isolating switch for standby sources be in during normal operation?
  • Battery case exterior maintenance should be performed on which cadence?
  • What does discharge pressure primarily indicate during a run test?
  • Voltage readings at the motor within __% below and __% above rated nameplate is acceptable?
  • Flexible hoses & connections: Which action sequence and cadence is recommended?
  • Which pump would be used where a suction lift is needed, such as from an underground reservoir, well river, or lake?
  • What is the significance of recording engine oil level and coolant during run tests, and how would you interpret abnormal readings?
  • When inspecting the isolating switch, what should be the state of the standby source?
  • Which weekly action is specified to protect the cooling system, specifically the heat exchanger?